1.Rating Voltage 1KV Aerial Cable
Standard GB12527-90, or design and produce as per client’s request.
Application performance: This products are suitable for fixed laying in power transmission and distribution lines Voltage rating of 0.6/1KV. The power cable is not limited by drop in level when being laid,and the ambient temperature shall not be lower than 0 centigrade. Permissible bending radius: D<25mm , ≥ 4 times of overall diameter of cable D≥6 times of overall diameter of cable(D is outer diameter of cable)
Model, Name and Appliance range
|
Model
|
Name
|
|
JKV
|
Cooper conductor PVC insulated aerial cable
|
|
JKLV
|
Aluminum conductor PVC insulated aerial cables
|
|
JKY
|
Cooper conductor PE insulated aerial cables
|
|
JKLY
|
Aluminum conductor PE insulated aerial cables
|
|
JKYJ
|
Cooper conductor XLPE insulated aerial cables
|
|
JKLYJ
|
Aluminum conductor XLPE insulated aerial cables
|
|
JKLGYJ
|
AGSR conductor XLPE insulated aerial cables
|
Application: this products is suitable for aerial fixed laying, house-service wire etc.
Specification range
|
Model
|
No. of cores
|
(mm2)nominal sections
|
|
JKV,JKLV,JKY,JKLY,JKYJ,JKLYJ,JKLGYJ
|
1
|
10~240
|
|
JKV,JKLV,JKY,JKLY,JKYJ,JKLYJ
|
2,3,4
|
10~120
|
|
JKLV,JKLY,JKLYJ
|
3+k
|
10~120
|
Note: K is neutral conductor with supporting body. Any section can mated with main cores, as per the request of power distribution project.
Basic technical parameter
|
Nominal sections
(mm2)
|
out diameter of conductor
(ã)
|
insulated nominal thickness
(ã)
|
Max. D.C.resistance of conductor at 20centigrade (Ω)
|
Min. insulation resistance of works temperature(Ω·km)
|
min tensile load
(KN)
|
|
hard cooper
|
soft cooper
|
aluminum
|
70centigrade
|
90centigrade
|
hard cooper cores
|
aluminum cores
|
|
10
|
3.99
|
1.0
|
1.906
|
1.83
|
3.08
|
0.0067
|
0.67
|
3.47
|
1.65
|
|
16
|
5.10
|
1.2
|
1.198
|
1.15
|
1.91
|
0.0065
|
0.65
|
5049
|
2.52
|
|
25
|
6.00
|
1.2
|
0.749
|
0.727
|
1.20
|
0.0054
|
0.54
|
8.46
|
3.76
|
|
35
|
7.00
|
1.4
|
0.540
|
0.524
|
0.868
|
0.0054
|
0.54
|
11.7
|
5.18
|
|
50
|
8.20
|
1.4
|
0.399
|
0.387
|
0.641
|
0.0046
|
0.46
|
16.5
|
7.01
|
|
70
|
10.0
|
1.4
|
0.276
|
0.268
|
0.443
|
0.0040
|
0.40
|
23.5
|
10.4
|
|
95
|
11.4
|
1.6
|
0.199
|
0.193
|
0.320
|
0.0039
|
0.39
|
31.8
|
13.7
|
|
120
|
13.0
|
1.6
|
0.158
|
0.153
|
0.253
|
0.0035
|
0.35
|
39.9
|
17.3
|
|
150
|
14.5
|
1.8
|
1.028
|
-
|
0.206
|
0.0035
|
0.35
|
49.5
|
21.0
|
|
185
|
16.2
|
2.0
|
0.1021
|
-
|
0.164
|
0.0035
|
0.35
|
61.8
|
26.7
|
|
240
|
18.3
|
2.0
|
0.0777
|
-
|
0.125
|
0.0034
|
0.34
|
79.8
|
34.7
|
2.Rating voltage 10KV, 35KV aerial cable
Standard GB14049-93, or design and produce as per clients' request
Application performance: this products is suitable for aerial fixed laying in power transmission or distribution network system. Max permissible continuous operatiing terperature is 90centigrade, Max. short-circuit(5 seconds at longest) temperature should not exceed 250centigrade. Permissible bending radius: single core ≥ 20 times of overall diameter of cable Multi cores≥ 15 times of overall diameter of cable
Model name and application range
|
Model
|
name
|
Applications
|
|
JKYJ
|
Cooper conductor XLPE insulated aerial cables
|
aerial fixed laying, cable keep certain distance, runing cable is allowed touch trees frequently
|
|
JKLYJ
|
Aluminum conductor XLPE insulated aerial cables
|
|
JKLGYJ
|
ACSR conductor XLPE insulated aerial cables
|
|
JKLYJ/Q
|
Aluminum conductor XLPE insulated light type aerial cables
|
aerial fixed laying, cable keep certain distance, runing cable is only allowed touch trees at a short time
|
|
JKLGYJ/Q
|
ACSR conductor XLPE insulated light type aeial cables
|
Specification range
|
model
|
No.of cores
|
rating voltage (KV)
|
|
10
|
35
|
|
nominal sections(mm2)
|
|
JKYJ
|
1,3
|
16~300
|
50~300
|
|
JKLYJ
|
1,3
|
25~300
|
70~300
|
|
JKLGYJ
|
1
|
16~300
|
50~300
|
|
JKLYJ/Q
|
1
|
25~300
|
70~300
|
|
JKLGYJ/Q
|
1
|
16~300
|
50~300
|
Basic technical parameter(exclude ACSR conductor)
|
nominal sections
(mm2)
|
diameter of conductor
(ã)
|
insulated nominal thickness
(ã)
|
D.C. resistance of conductor ≤Ω/km
|
Coductor tensile load ≥N
|
|
10KV
|
35
KV
|
|
light type
|
usual type
|
hard cooper
|
soft cooper
|
aluminum
|
aluminum
|
cooper
|
|
16
|
5.1
|
-
|
3.4
|
-
|
-
|
1.15
|
1.91
|
-
|
-
|
|
25
|
6.0
|
2.5
|
3.4
|
-
|
0.749
|
0.727
|
1.20
|
3762
|
8465
|
|
35
|
7.0
|
2.5
|
3.4
|
-
|
0.540
|
0.524
|
0.868
|
5177
|
11731
|
|
50
|
8.2
|
2.5
|
3.4
|
9.3
|
0.399
|
0.387
|
0.641
|
7011
|
16502
|
|
70
|
10.0
|
2.5
|
3.4
|
9.3
|
0.276
|
0.268
|
0.443
|
10354
|
23461
|
|
95
|
11.4
|
2.5
|
3.4
|
9.3
|
0.199
|
0.193
|
0.320
|
13727
|
31759
|
|
120
|
13.0
|
2.5
|
3.4
|
9.3
|
0.158
|
0.153
|
0.253
|
17339
|
39911
|
|
150
|
14.5
|
2.5
|
3.4
|
9.3
|
0.128
|
-
|
0.206
|
21033
|
49505
|
|
185
|
16.2
|
2.5
|
3.4
|
9.3
|
0.1201
|
-
|
0.164
|
26732
|
61846
|
|
240
|
18.3
|
2.5
|
3.4
|
9.3
|
0.0777
|
-
|
0.125
|
34679
|
79823
|
|
300
|
20.4
|
2.5
|
3.4
|
9.3
|
0.0619
|
-
|
0.100
|
43349
|
99788
|
|